elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Impressum | Datenschutz | Barrierefreiheit | Kontakt | English
Schriftgröße: [-] Text [+]

Development and integration of link-side angular position sensors for state estimation and calibration of a tendon-driven variable stiffness robotic finger.

Schröter, Aurel (2026) Development and integration of link-side angular position sensors for state estimation and calibration of a tendon-driven variable stiffness robotic finger. Masterarbeit, Hochschule München.

[img] PDF - Nur DLR-intern zugänglich
7MB

Kurzfassung

Tendon-driven robotic fingers with variable stiffness allow a safe and compliant interaction with the environment, and their stiffness can be adapted to the task at hand. In the DLR SmartHand finger, the actuators are placed outside the finger and drive the joints through coupled tendons with progressive springs. Currently, the joint angles can therefore only be estimated indirectly from the servo positions and offsets, the spring elongations and the coupling matrix. The difficulty with this is that model errors from the spring and coupling matrix, as well as friction, add uncertainty to the estimate. This estimate in turn is only possible with calibrated servo offsets that had to be determined by a manual calibration in a clamped reference pose of the joints. In this thesis, link-side joint angle sensors were integrated into the finger to enable a direct measurement of the joint state and with that an automatic servo offset calibration. For the measurement, three on-axis 14-bit absolute magnetic encoders (AS5048B) on custom PCBs were placed in the joints and connected by a flexible flat cable routed through the finger. With the measured joint angles, the servo offsets remain the only unknowns and can be calculated directly. A kinematic, dynamic and actuation model of the finger was built, and a feedforward as well as an impedance controller with gravity and friction compensation were tested.

elib-URL des Eintrags:https://elib.dlr.de/230041/
Dokumentart:Hochschulschrift (Masterarbeit)
Titel:Development and integration of link-side angular position sensors for state estimation and calibration of a tendon-driven variable stiffness robotic finger.
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Schröter, AurelAurel.Schroeter (at) dlr.deNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
DLR-Supervisor:
BeitragsartDLR-SupervisorInstitution oder E-Mail-AdresseDLR-Supervisor-ORCID-iD
Thesis advisorFriedl, WernerWerner.Friedl (at) dlr.dehttps://orcid.org/0000-0003-3002-7274
Datum:25 November 2026
Open Access:Nein
Seitenanzahl:157
Status:veröffentlicht
Stichwörter:Robot hand, calibration, sensors
Institution:Hochschule München
HGF - Forschungsbereich:Luftfahrt, Raumfahrt und Verkehr
HGF - Programm:Raumfahrt
HGF - Programmthema:Robotik
DLR - Schwerpunkt:Raumfahrt
DLR - Forschungsgebiet:R RO - Robotik
DLR - Teilgebiet (Projekt, Vorhaben):R - Mehrfingrige Roboterhände
Standort: Oberpfaffenhofen
Institute & Einrichtungen:Institut für Robotik und Mechatronik (ab 2013)
Hinterlegt von: Friedl, Werner
Hinterlegt am:26 Nov 2026 08:08
Letzte Änderung:26 Nov 2026 08:08

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
OpenAIRE Validator logo electronic library verwendet EPrints
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.