Braun, Hannah und Okhravi, Mahdi und Castellini, Claudio (2026) Incremental Deep Learning for Single-Finger Myoelectric Control: A Comparative Closed-Loop Study of CNN and LSTM Architectures. In: 11th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, BioRob 2026, Seiten 1001-1008. IEEE. 11th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), 2026-08-01 - 2026-08-04, Edmonton, AB, Canada. doi: 10.1109/BioRob66782.2026.11681092. ISBN 979-833154813-1. ISSN 2155-1774.
Dieses Archiv kann nicht den Volltext zur Verfügung stellen.
Offizielle URL: https://ieeexplore.ieee.org/abstract/document/11681092
Kurzfassung
Target achievement control tests provide a standardized way to quantify closed-loop myoelectric control during continuous target acquisition. We compared two electromyography-to-kinematics regression controllers for single-finger control using 32-channel surface electromyography: a pretrained dilated residual convolutional neural network regressor (996k parameters) and a lightweight long shortterm memory regressor without pretraining (65k parameters). Ten non-disabled participants completed a counterbalanced within-subject crossover study. For each controller condition, participant-specific training was performed and target achievement control was evaluated in two blocks: before and after a targeted incremental fine-tuning step using additional data collected from difficult targets. Performance was assessed using completion rate, median time-to-success, overshoot count, and time spent outside the target region after first entry. After participant-specific training, both controllers achieved comparable target achievement control performance across all primary outcomes (|dz|<=0.16, all p>0.6). As the CNN was pretrained on only six participants, this equivalence need not hold at larger pretraining scales. Incremental fine-tuning produced large improvements for both controllers (dz>0.8), increasing completion rate by 12-17 percentage points and reducing movement time by 1.0-1.4 s and post-entry instability by 3-5 s per target. These results suggest that participantspecific incremental learning can enable a lightweight model without pretraining to match a deeper pretrained architecture in single-finger myoelectric control, while targeted fine-tuning provides a robust mechanism to improve speed and stability during use.
| elib-URL des Eintrags: | https://elib.dlr.de/227718/ | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dokumentart: | Konferenzbeitrag (Vortrag) | ||||||||||||||||
| Titel: | Incremental Deep Learning for Single-Finger Myoelectric Control: A Comparative Closed-Loop Study of CNN and LSTM Architectures | ||||||||||||||||
| Autoren: |
| ||||||||||||||||
| Datum: | 1 September 2026 | ||||||||||||||||
| Erschienen in: | 11th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, BioRob 2026 | ||||||||||||||||
| Referierte Publikation: | Ja | ||||||||||||||||
| Open Access: | Nein | ||||||||||||||||
| Gold Open Access: | Nein | ||||||||||||||||
| In SCOPUS: | Ja | ||||||||||||||||
| In ISI Web of Science: | Nein | ||||||||||||||||
| DOI: | 10.1109/BioRob66782.2026.11681092 | ||||||||||||||||
| Seitenbereich: | Seiten 1001-1008 | ||||||||||||||||
| Verlag: | IEEE | ||||||||||||||||
| ISSN: | 2155-1774 | ||||||||||||||||
| ISBN: | 979-833154813-1 | ||||||||||||||||
| Status: | veröffentlicht | ||||||||||||||||
| Stichwörter: | myoelectric control | ||||||||||||||||
| Veranstaltungstitel: | 11th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) | ||||||||||||||||
| Veranstaltungsort: | Edmonton, AB, Canada | ||||||||||||||||
| Veranstaltungsart: | internationale Konferenz | ||||||||||||||||
| Veranstaltungsbeginn: | 1 August 2026 | ||||||||||||||||
| Veranstaltungsende: | 4 August 2026 | ||||||||||||||||
| HGF - Forschungsbereich: | Luftfahrt, Raumfahrt und Verkehr | ||||||||||||||||
| HGF - Programm: | Raumfahrt | ||||||||||||||||
| HGF - Programmthema: | Robotik | ||||||||||||||||
| DLR - Schwerpunkt: | Raumfahrt | ||||||||||||||||
| DLR - Forschungsgebiet: | R RO - Robotik | ||||||||||||||||
| DLR - Teilgebiet (Projekt, Vorhaben): | R - Medizinische Assistenzsysteme [RO], R - Basistechnologien [RO] | ||||||||||||||||
| Standort: | Oberpfaffenhofen | ||||||||||||||||
| Institute & Einrichtungen: | Institut für Robotik und Mechatronik (ab 2013) | ||||||||||||||||
| Hinterlegt von: | Strobl, Dr.-Ing. Klaus H. | ||||||||||||||||
| Hinterlegt am: | 12 Okt 2026 16:44 | ||||||||||||||||
| Letzte Änderung: | 12 Okt 2026 16:44 |
Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags