Long-term behavior, accuracy and drift of LI-200 pyranometers as radiation sensors in Rotating Shadowband Irradiometers (RSI)

Geuder, Norbert and Affolter, Roman and Kraas, Birk and Wilbert, Stefan (2014) Long-term behavior, accuracy and drift of LI-200 pyranometers as radiation sensors in Rotating Shadowband Irradiometers (RSI). Energy Procedia (49), pp. 2330-2339. Elsevier. doi: 10.1016/j.egypro.2014.03.247. ISSN 1876-6102.

[img] PDF (Long-term behavior, accuracy and drift of LI-200 pyranometers)
2MB

Official URL: http://www.sciencedirect.com/science/article/pii/S1876610214007012

Abstract

Rotating Shadowband Irradiometers (RSI) are frequently used for solar resource assessment at remote sites due to their significantly higher robustness for soiling, their lower power and maintenance requirements and their cheaper acquisition and operation in contrast to pyrheliometer on tracker systems. The primordial lower accuracy of their photodiode sensor, usually a LI-200 pyranometer from LI-COR Inc., is mainly caused by restrictions of their spectral sensitivity and temperature dependence. However accuracy is notably increased by application of corrections to the raw sensor response. Thus, finally a coincidence of DNI measurements from RSIs with high-precision pyrheliometer measurements within 15 W/m2 (root mean square deviation for 10 min averages) for actual values, less than 3% for daily DNI and within approximately 1.5% of the monthly and annual sum is reached. Within this contribution, the long-term behavior of the LI-COR sensor is examined with regard to the drift of the photodiode sensitivity. This is analyzed from recalibrations of 30 sensors after one to four years and from long-term studies lasting from one to several years. If a significant drift appears, the corresponding uncertainties can be reduced through recalculation of the previous measurement data for the total measurement campaign. Furthermore, studies about the coincidence and deviation of the responses for global, diffuse and direct irradiance of RSI measurements between several individual RSIs and to reference measurements from high-precision thermopiles are presented for different time resolutions.

Item URL in elib:https://elib.dlr.de/91766/
Document Type:Article
Title:Long-term behavior, accuracy and drift of LI-200 pyranometers as radiation sensors in Rotating Shadowband Irradiometers (RSI)
Authors:
AuthorsInstitution or Email of AuthorsAuthor's ORCID iDORCID Put Code
Geuder, NorbertUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Affolter, RomanCSP ServicesUNSPECIFIEDUNSPECIFIED
Kraas, BirkCSP ServicesUNSPECIFIEDUNSPECIFIED
Wilbert, StefanUNSPECIFIEDhttps://orcid.org/0000-0003-3573-3004UNSPECIFIED
Date:2014
Journal or Publication Title:Energy Procedia
Refereed publication:Yes
Open Access:Yes
Gold Open Access:No
In SCOPUS:Yes
In ISI Web of Science:No
DOI:10.1016/j.egypro.2014.03.247
Page Range:pp. 2330-2339
Publisher:Elsevier
Series Name:El Sevier
ISSN:1876-6102
Status:Published
Keywords:irradiation measurement; DNI; pyranometer; photodiode; drift; accuracy; Rotating Shadowband Irradiometer; RSI; RSP
HGF - Research field:Energy
HGF - Program:Renewable Energies
HGF - Program Themes:Concentrating Solar Systems (old)
DLR - Research area:Energy
DLR - Program:E SF - Solar research
DLR - Research theme (Project):E - Qualification (old)
Location: Köln-Porz
Institutes and Institutions:Institute of Solar Research > Qualifizierung
Deposited By: Kruschinski, Anja
Deposited On:11 Nov 2014 11:25
Last Modified:22 Jun 2023 10:09

Repository Staff Only: item control page

Browse
Search
Help & Contact
Information
electronic library is running on EPrints 3.3.12
Website and database design: Copyright © German Aerospace Center (DLR). All rights reserved.