elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Impressum | Datenschutz | Kontakt | English
Schriftgröße: [-] Text [+]

Long-term behavior, accuracy and drift of LI-200 pyranometers as radiation sensors in Rotating Shadowband Irradiometers (RSI)

Geuder, Norbert und Affolter, Roman und Kraas, Birk und Wilbert, Stefan (2014) Long-term behavior, accuracy and drift of LI-200 pyranometers as radiation sensors in Rotating Shadowband Irradiometers (RSI). Energy Procedia (49), Seiten 2330-2339. Elsevier. doi: 10.1016/j.egypro.2014.03.247. ISSN 1876-6102.

[img] PDF (Long-term behavior, accuracy and drift of LI-200 pyranometers)
2MB

Offizielle URL: http://www.sciencedirect.com/science/article/pii/S1876610214007012

Kurzfassung

Rotating Shadowband Irradiometers (RSI) are frequently used for solar resource assessment at remote sites due to their significantly higher robustness for soiling, their lower power and maintenance requirements and their cheaper acquisition and operation in contrast to pyrheliometer on tracker systems. The primordial lower accuracy of their photodiode sensor, usually a LI-200 pyranometer from LI-COR Inc., is mainly caused by restrictions of their spectral sensitivity and temperature dependence. However accuracy is notably increased by application of corrections to the raw sensor response. Thus, finally a coincidence of DNI measurements from RSIs with high-precision pyrheliometer measurements within 15 W/m2 (root mean square deviation for 10 min averages) for actual values, less than 3% for daily DNI and within approximately 1.5% of the monthly and annual sum is reached. Within this contribution, the long-term behavior of the LI-COR sensor is examined with regard to the drift of the photodiode sensitivity. This is analyzed from recalibrations of 30 sensors after one to four years and from long-term studies lasting from one to several years. If a significant drift appears, the corresponding uncertainties can be reduced through recalculation of the previous measurement data for the total measurement campaign. Furthermore, studies about the coincidence and deviation of the responses for global, diffuse and direct irradiance of RSI measurements between several individual RSIs and to reference measurements from high-precision thermopiles are presented for different time resolutions.

elib-URL des Eintrags:https://elib.dlr.de/91766/
Dokumentart:Zeitschriftenbeitrag
Titel:Long-term behavior, accuracy and drift of LI-200 pyranometers as radiation sensors in Rotating Shadowband Irradiometers (RSI)
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Geuder, Norbertn.geuder (at) cspservices.deNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Affolter, RomanCSP ServicesNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Kraas, BirkCSP ServicesNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Wilbert, Stefanstefan.wilbert (at) dlr.dehttps://orcid.org/0000-0003-3573-3004NICHT SPEZIFIZIERT
Datum:2014
Erschienen in:Energy Procedia
Referierte Publikation:Ja
Open Access:Ja
Gold Open Access:Nein
In SCOPUS:Ja
In ISI Web of Science:Nein
DOI:10.1016/j.egypro.2014.03.247
Seitenbereich:Seiten 2330-2339
Verlag:Elsevier
Name der Reihe:El Sevier
ISSN:1876-6102
Status:veröffentlicht
Stichwörter:irradiation measurement; DNI; pyranometer; photodiode; drift; accuracy; Rotating Shadowband Irradiometer; RSI; RSP
HGF - Forschungsbereich:Energie
HGF - Programm:Erneuerbare Energie
HGF - Programmthema:Konzentrierende Solarsysteme (alt)
DLR - Schwerpunkt:Energie
DLR - Forschungsgebiet:E SF - Solarforschung
DLR - Teilgebiet (Projekt, Vorhaben):E - Qualifizierung (alt)
Standort: Köln-Porz
Institute & Einrichtungen:Institut für Solarforschung > Qualifizierung
Hinterlegt von: Kruschinski, Anja
Hinterlegt am:11 Nov 2014 11:25
Letzte Änderung:22 Jun 2023 10:09

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.