elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Impressum | Datenschutz | Kontakt | English
Schriftgröße: [-] Text [+]

Photogrammetric block adjustment using MOMS-2P imagery of three intersecting stereo-strips

Kornus, Wolfgang und Lehner, Manfred und Schroeder, Manfred (1999) Photogrammetric block adjustment using MOMS-2P imagery of three intersecting stereo-strips. In: Proceedings of ISPRS Workshop on "Direct versus indirect methods of sensor orientation", Barcelona, Spanien, 25.-26.11.1999. ISPRS Workshop on "Direct versus indirect methods of sensor orientation", Barcelona, Spanien, 25.-26.11.1999.

Dieses Archiv kann nicht den Volltext zur Verfügung stellen.

Kurzfassung

Since May 1996 the German multi-line-scanner MOMS-2P (Modular Optoelectronic Multi-spectral Stereoscanner) is attached to the remote sensing module PRIRODA of the Russian space station MIR. Its stereo module with three differently oriented lenses allows for the acquisition of threefold along track stereoscopic imagery. After a long break in 1997, caused by the collision of MIR with a PROGRESS spacecraft, MOMS-2P is continously operating again since January 1998. The paper describes the geometric inflight-calibration and the simultaneous sensor orientation by photogrammetric block adjustment using imagery of the three intersecting MOMS-2P data takes T083C, T08C5 and T08FE, all covering parts of South Germany. Here, for the first time a block adjustment is applied to spaceborne 3-line-imagery of three different MOMS-2P data takes. The functional model for reconstruction of the exterior orientation is based on the principle of orientation images, the reconstruction of the interior orientation involves a set of 5 parameters per CCD-array and data take. The parameters and their changes are estimated in the block adjustment using 252 control points (inverse photogrammetry). Next, the accuracy of point determination with small subsets of control points is assessed using the remaining control points as independent checkpoints. In a further step a digital elevation model is derived from a dense cloud of homologous points, which is transformed into object space using the estimated interior orientation. The comparison with a reference DEM of superior accuracy showed unexpected systematic undulations in the MOMS-DEM. The major parts of the disturbances could be modelled, leading to a mean empirical height accuracy of 8 m for a 90 km x 50 km wide area. If all disturbances were eliminated, 7 m would be achieved. The results finally are summarized and conlusions are drawn.

elib-URL des Eintrags:https://elib.dlr.de/8864/
Dokumentart:Konferenzbeitrag (Paper)
Zusätzliche Informationen: LIDO-Berichtsjahr=2000,
Titel:Photogrammetric block adjustment using MOMS-2P imagery of three intersecting stereo-strips
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Kornus, WolfgangNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Lehner, ManfredNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Schroeder, ManfredNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Datum:1999
Erschienen in:Proceedings of ISPRS Workshop on "Direct versus indirect methods of sensor orientation", Barcelona, Spanien, 25.-26.11.1999
Open Access:Nein
Gold Open Access:Nein
In SCOPUS:Nein
In ISI Web of Science:Nein
Herausgeber:
HerausgeberInstitution und/oder E-Mail-Adresse der HerausgeberHerausgeber-ORCID-iDORCID Put Code
Institute of Geanatics Generalitat de Catalunya & Universitat Politecuica de Catalunya, NICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Status:veröffentlicht
Veranstaltungstitel:ISPRS Workshop on "Direct versus indirect methods of sensor orientation", Barcelona, Spanien, 25.-26.11.1999
Veranstalter :Institut Cartografic de Catalunya (ICC)
HGF - Forschungsbereich:Verkehr und Weltraum (alt)
HGF - Programm:Weltraum (alt)
HGF - Programmthema:W EO - Erdbeobachtung
DLR - Schwerpunkt:Weltraum
DLR - Forschungsgebiet:W EO - Erdbeobachtung
DLR - Teilgebiet (Projekt, Vorhaben):NICHT SPEZIFIZIERT
Standort: Oberpfaffenhofen
Institute & Einrichtungen:Institut für Optoelektronik
Hinterlegt von: DLR-Beauftragter, elib
Hinterlegt am:09 Mai 2006
Letzte Änderung:06 Jan 2010 23:20

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.