A fast double shutter system for CCD image sensors

Geisler, Reinhard (2014) A fast double shutter system for CCD image sensors. Measurement Science and Technology, 25 (2), pp. 1-7. Institute of Physics (IOP) Publishing. doi: 10.1088/0957-0233/25/2/025404. ISSN 0957-0233.

Full text not available from this repository.

Official URL: http://iopscience.iop.org/0957-0233/25/2/025404/pdf/0957-0233_25_2_025404.pdf

Abstract

A new fast shutter system for CCD sensor based cameras is presented. This system is capable of providing for the first time short exposure times for two consecutive frames recorded in fast succession with high spatial resolutions. In addition, a third frame can be recorded with a long exposure time, this then corresponding to the well-known ’double shutter’. Measurement techniques such as Particle Image Velocimetry (PIV) will benefit from the new fast shutter when being used in bright environments. Using the optional third frame, advanced evaluation schemes can be implemented to measure acceleration, increase the dynamic range of the velocity measurements or reduce the number of false matches (’ghost particles’) in tomographic PIV or particle tracking. It will be shown that this new shutter timing outperforms even the latest commercially available high-speed cameras.

Item URL in elib:https://elib.dlr.de/84061/
Document Type:Article
Additional Information:Meas. Sci. Technol. 25 (2014) 025404 (6pp)
Title:A fast double shutter system for CCD image sensors
Authors:
AuthorsInstitution or Email of AuthorsAuthor's ORCID iDORCID Put Code
Geisler, ReinhardUNSPECIFIEDhttps://orcid.org/0009-0006-8838-3713UNSPECIFIED
Date:2014
Journal or Publication Title:Measurement Science and Technology
Refereed publication:Yes
Open Access:No
Gold Open Access:No
In SCOPUS:Yes
In ISI Web of Science:Yes
Volume:25
DOI:10.1088/0957-0233/25/2/025404
Page Range:pp. 1-7
Publisher:Institute of Physics (IOP) Publishing
ISSN:0957-0233
Status:Published
Keywords:CCD, high-speed camera, double shutter, particle image velocimetry, PIV, particle tracking, multi-frame
HGF - Research field:Aeronautics, Space and Transport
HGF - Program:Aeronautics
HGF - Program Themes:Aircraft Research (old)
DLR - Research area:Aeronautics
DLR - Program:L AR - Aircraft Research
DLR - Research theme (Project):L - Simulation & Validation (old)
Location: Göttingen
Institutes and Institutions:Institute of Aerodynamics and Flow Technology > Experimental Methods
Deposited By: Micknaus, Ilka
Deposited On:17 Feb 2014 13:48
Last Modified:06 Nov 2023 15:08

Repository Staff Only: item control page

Browse
Search
Help & Contact
Information
electronic library is running on EPrints 3.3.12
Website and database design: Copyright © German Aerospace Center (DLR). All rights reserved.