Birk, Manfred and Wagner, Georg (2012) Temperature-dependent air broadening of water in the 1250–1750 cm-1 range. Journal of Quantitative Spectroscopy and Radiative Transfer, 113 (11), pp. 889-928. Elsevier. doi: 10.1016/j.jqsrt.2011.12.013.
Full text not available from this repository.
Abstract
A Bruker IFS120HR Fourier-transform spectrometer has been used to investigate air broadening of water vapor at a spectral resolution of 3x10-3 cm-1 in the wavenumber range 1250–1750 cm-1. A new method for generating water vapor/air mixtures employing a 800l stainless steel mixing vessel and a steady flow through the absorption cell has been developed. A total of 46 measurements have been recorded, 33 (26 water/air, 7 pure water) of which have been used in the final analysis. The measurements covered the temperature range 205–315 K, total air pressure range 50–1000 mb, water partial pressure range 0.001–5 mb, absorption path range 16–8500 cm and provided sufficient redundancy. Transmittance spectra corrected for various instrumental error sources were used in an automated single spectrum fit line parameter retrieval based on the Voigt profile. Average gas temperatures were fitted from retrieved water linestrengths. From the retrieved Lorentzian line widths of each individual transition the air and self-broadening parameters and temperature exponents, gair, gself, nair, nself, or a subset there of were fitted in an automated procedure. Various methods for validation of data product accuracy and data reduction model as well as comprehensive error analysis were applied. In total 593 gair, 459 nair and 469 gself values are reported, uncertainties for gair are given for reference temperatures 296 and 220 K. Only data are reported where the gair uncertainty is <2% or the gair,220K uncertainty is <5%. The average uncertainties for gair, gair,220K, nair, and gself are 0.7%, 2.2%, 0.07, and 3%, respectively. Comparisons with recent experimental work and HITRAN2004 and HITRAN2008 are presented.
Item URL in elib: | https://elib.dlr.de/75794/ | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Document Type: | Article | |||||||||
Title: | Temperature-dependent air broadening of water in the 1250–1750 cm-1 range | |||||||||
Authors: |
| |||||||||
Date: | 2012 | |||||||||
Journal or Publication Title: | Journal of Quantitative Spectroscopy and Radiative Transfer | |||||||||
Refereed publication: | Yes | |||||||||
Open Access: | No | |||||||||
Gold Open Access: | No | |||||||||
In SCOPUS: | Yes | |||||||||
In ISI Web of Science: | Yes | |||||||||
Volume: | 113 | |||||||||
DOI: | 10.1016/j.jqsrt.2011.12.013 | |||||||||
Page Range: | pp. 889-928 | |||||||||
Publisher: | Elsevier | |||||||||
Status: | Published | |||||||||
Keywords: | pressure broadening parameters, temperature dependence, water vapor, infrared, spectroscopic data base | |||||||||
HGF - Research field: | Aeronautics, Space and Transport (old) | |||||||||
HGF - Program: | Space (old) | |||||||||
HGF - Program Themes: | W EO - Erdbeobachtung | |||||||||
DLR - Research area: | Space | |||||||||
DLR - Program: | W EO - Erdbeobachtung | |||||||||
DLR - Research theme (Project): | W - Vorhaben Spektrometrische Verfahren und Konzepte der Fernerkundung (old) | |||||||||
Location: | Oberpfaffenhofen | |||||||||
Institutes and Institutions: | Remote Sensing Technology Institute > Experimental Methods | |||||||||
Deposited By: | Wagner, Dr.rer.nat. Georg | |||||||||
Deposited On: | 30 May 2012 08:21 | |||||||||
Last Modified: | 06 Sep 2019 15:28 |
Repository Staff Only: item control page