Gieß, Peter-Anton und Mullaert, Arnold (2007) AN EXPERIMENTAL INVESTIGATION OF AN IMPROVED FILM-COOLING CONFIGURATION AT A TURBINE VANE ENDWALL TO REDUCE THE AMOUNT OF COOLANT. In: 7th European Conference on Turbomachinery, Fluid Dynamics and Thermodynamics, 5-9 March 2007, Athens-Greece, Seiten 1095-1104. 7th European Conference on Turbomachinery, 2007-03-05 - 2007-03-09, Athens, Greece.
Dieses Archiv kann nicht den Volltext zur Verfügung stellen.
Kurzfassung
In the Windtunnel for Straight Cascades (EGG) at DLR, Goettingen, thermodynamic investigations were performed
applying an improved cooling scheme to establish film cooling at the endwall of a first stage stator.
Based on the results from an earlier project the slot position in front of the cascade, as well as the number
and the arrangement of the cooling holes within the passage were improved to reduce the necessary amount of
coolant. The experiments were carried out at an exit Mach number of 1.0 and at a downstream Reynolds number
of 850,000. An infrared camera was used to collect the thermal data of the homogeneous heated endwall, which
was appended with electric operated heating foils. The temperature of the coolant flow was adjustable which was
necessary for the use of the superposition method. Therefore, the values for heat transfer coefficients and film cooling effectiveness were obtained under similar boundary conditions.
The experiments proved the progress in coolant management achieved when applying the new improved cooling configuration instead of the previous one. The slot coolant mass flow rate was more than halved without reducing
the film cooling effectiveness. The holes rearranged within the passage close to the pressure side significantly improve platform cooling at a reduced demand of coolant, too.
| elib-URL des Eintrags: | https://elib.dlr.de/53331/ | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dokumentart: | Konferenzbeitrag (Vortrag) | ||||||||||||
| Titel: | AN EXPERIMENTAL INVESTIGATION OF AN IMPROVED FILM-COOLING CONFIGURATION AT A TURBINE VANE ENDWALL TO REDUCE THE AMOUNT OF COOLANT | ||||||||||||
| Autoren: |
| ||||||||||||
| Datum: | März 2007 | ||||||||||||
| Erschienen in: | 7th European Conference on Turbomachinery, Fluid Dynamics and Thermodynamics, 5-9 March 2007, Athens-Greece | ||||||||||||
| Referierte Publikation: | Ja | ||||||||||||
| Open Access: | Nein | ||||||||||||
| Gold Open Access: | Nein | ||||||||||||
| In SCOPUS: | Nein | ||||||||||||
| In ISI Web of Science: | Ja | ||||||||||||
| Seitenbereich: | Seiten 1095-1104 | ||||||||||||
| Status: | veröffentlicht | ||||||||||||
| Stichwörter: | Coolant ejection, platform, IR-thermography, heat transfer, film cooling effectiveness, reduced amount of coolant, improved cooling geometry | ||||||||||||
| Veranstaltungstitel: | 7th European Conference on Turbomachinery | ||||||||||||
| Veranstaltungsort: | Athens, Greece | ||||||||||||
| Veranstaltungsart: | internationale Konferenz | ||||||||||||
| Veranstaltungsbeginn: | 5 März 2007 | ||||||||||||
| Veranstaltungsende: | 9 März 2007 | ||||||||||||
| Veranstalter : | National Technical University Athens | ||||||||||||
| HGF - Forschungsbereich: | Energie | ||||||||||||
| HGF - Programm: | Rationelle Energieumwandlung (alt) | ||||||||||||
| HGF - Programmthema: | E VG - Verbrennungs- und Gasturbinentechnik (alt) | ||||||||||||
| DLR - Schwerpunkt: | Energie | ||||||||||||
| DLR - Forschungsgebiet: | E VG - Verbrennungs- und Gasturbinentechnik | ||||||||||||
| DLR - Teilgebiet (Projekt, Vorhaben): | E - Gasturbine (alt) | ||||||||||||
| Standort: | Göttingen | ||||||||||||
| Institute & Einrichtungen: | Institut für Antriebstechnik > Turbine > Turbinentechnologie | ||||||||||||
| Hinterlegt von: | Klein, Stephanie | ||||||||||||
| Hinterlegt am: | 15 Feb 2008 | ||||||||||||
| Letzte Änderung: | 24 Apr 2024 19:16 |