Feles, Sebastian und Diegeler, Sebastian und Henschenmacher, Bernd und Baumstark-Khan, Christa und Hellweg, Christine Elisabeth (2026) Comparison of Dual-Luciferase® Reporter Assay and a Stably Transfected NF-κB Reporter Cell Line for Detecting TNF-α and X-Ray-Induced Pathway Activation. Methods and Protocols, 9 (6), Seite 164. Multidisciplinary Digital Publishing Institute (MDPI). doi: 10.3390/mps9060164. ISSN 2409-9279.
|
PDF
- Verlagsversion (veröffentlichte Fassung)
1MB |
Offizielle URL: https://dx.doi.org/10.3390/mps9060164
Kurzfassung
The transcription factor nuclear factor kappa B (NF-κB) is a central regulator of inflammatory and genotoxic stress responses and is involved in immune function and disease pathogenesis. Reporter assays are widely used to quantify NF-κB activation, yet systematic benchmarks between transient dual-luciferase and stable fluorescent formats under harmonized conditions are lacking. We compared a transient Dual-Luciferase® Reporter (DLR™) assay in HEK293 cells with the stably transfected HEK-pNF-κB-d2EGFP/Neo L2 cell line using recombinant TNF-α and X-rays as stimuli. Dynamic range, limit of detection (LOD), signal-to-noise ratio (S/N), and half-maximal effective concentrations and doses (EC50, ED50) were derived from four-parameter logistic modeling. The HEK-pNF-κB-d2EGFP/Neo L2 line showed higher sensitivity to TNF-α (EC50 = 0.31 ng/mL) than the DLR™ assay (1.2–2.0 ng/mL) and a lower LOD, whereas the DLR™ assay provided better temporal resolution, revealing assay-specific signal decline attributable to reporter stability and readout kinetics. For X-ray exposure, both systems showed comparable potency (EC50 ≈ 5–8 Gy), while the stable cell line maintained superior S/N. Both reporter systems support high-throughput and mechanistic applications: the DLR™ assay offers versatility across cell types, while the HEK-pNF-κB-d2EGFP/Neo L2 line provides higher sensitivity, dynamic range, and single-cell resolution.
| elib-URL des Eintrags: | https://elib.dlr.de/229191/ | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dokumentart: | Zeitschriftenbeitrag | ||||||||||||||||||||||||
| Titel: | Comparison of Dual-Luciferase® Reporter Assay and a Stably Transfected NF-κB Reporter Cell Line for Detecting TNF-α and X-Ray-Induced Pathway Activation | ||||||||||||||||||||||||
| Autoren: |
| ||||||||||||||||||||||||
| Datum: | 9 November 2026 | ||||||||||||||||||||||||
| Erschienen in: | Methods and Protocols | ||||||||||||||||||||||||
| Referierte Publikation: | Ja | ||||||||||||||||||||||||
| Open Access: | Ja | ||||||||||||||||||||||||
| Gold Open Access: | Ja | ||||||||||||||||||||||||
| In SCOPUS: | Ja | ||||||||||||||||||||||||
| In ISI Web of Science: | Ja | ||||||||||||||||||||||||
| Band: | 9 | ||||||||||||||||||||||||
| DOI: | 10.3390/mps9060164 | ||||||||||||||||||||||||
| Seitenbereich: | Seite 164 | ||||||||||||||||||||||||
| Verlag: | Multidisciplinary Digital Publishing Institute (MDPI) | ||||||||||||||||||||||||
| ISSN: | 2409-9279 | ||||||||||||||||||||||||
| Status: | veröffentlicht | ||||||||||||||||||||||||
| Stichwörter: | NF-κB reporter assay; Dual-Luciferase Reporter® assay; destabilized enhanced green fluorescent protein; transient transfection; stable transfection; assay sensitivity; dynamic range; human embryonic kidney cells | ||||||||||||||||||||||||
| HGF - Forschungsbereich: | Luftfahrt, Raumfahrt und Verkehr | ||||||||||||||||||||||||
| HGF - Programm: | Raumfahrt | ||||||||||||||||||||||||
| HGF - Programmthema: | Forschung unter Weltraumbedingungen | ||||||||||||||||||||||||
| DLR - Schwerpunkt: | Raumfahrt | ||||||||||||||||||||||||
| DLR - Forschungsgebiet: | R FR - Forschung unter Weltraumbedingungen | ||||||||||||||||||||||||
| DLR - Teilgebiet (Projekt, Vorhaben): | R - RepairChoice, R - Strahlung & Hypoxie | ||||||||||||||||||||||||
| Standort: | Köln-Porz | ||||||||||||||||||||||||
| Institute & Einrichtungen: | Institut für Luft- und Raumfahrtmedizin > Strahlenbiologie Institut für Luft- und Raumfahrtmedizin > :enviTechBase Institut für Luft- und Raumfahrtmedizin > Leitungsbereich ME | ||||||||||||||||||||||||
| Hinterlegt von: | Kopp, Kerstin | ||||||||||||||||||||||||
| Hinterlegt am: | 12 Nov 2026 13:26 | ||||||||||||||||||||||||
| Letzte Änderung: | 12 Nov 2026 13:26 |
Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags