El Idrissi, Rafika und Beckmann, Robert und Vallabhaneni, Saikrishna und Schuldt, Frank und Maydell, Karsten (2026) Modelling and Simulation of a Resilient and Straightforward Energy Management System for a DC Microgrid in a Cruise Ship Firezone. Energies, 19 (11). Multidisciplinary Digital Publishing Institute (MDPI). doi: 10.3390/en19112512. ISSN 1996-1073.
|
PDF
- Verlagsversion (veröffentlichte Fassung)
2MB |
Offizielle URL: https://www.mdpi.com/1996-1073/19/11/2512#article-metrics-statistics-views
Kurzfassung
This paper presents a practical and communication-independent energy management system (EMS) for a DC microgrid supply within the firezone of a cruise ship. The proposed approach prioritizes operational reliability and fault tolerance under emergency conditions, where communication availability and control complexity should be minimized. The proposed DC microgrid integrates photovoltaic systems (PVs), fuel cell systems (FCs), and lithium-iron-phosphate (LFP) battery energy storage systems (BESSs), coordinated through a rule-based EMS combined with droop-controlled converters. The electrical topology considered in this study is a collaborative development of the project consortium of the publicly funded project Sustainable DC Systems (SuSy), featuring a novel configuration with two independent horizontal busbars for the Cabin Area Distribution (CAD) and Technical Area Distribution (TAD). The EMS can manage two operational scenarios: (i) regular operation, with two decentralized droop controls where power generation is distributed among all generators based on their respective capacities, and a power curtailment strategy is applied to prevent overcharging of BESSs; and (ii) irregular operation, where a fault on one of the vertical busbars triggers the use of reserved battery storage capacity on both sides of the ship and activates load-shedding to ensure continued operation of critical loads and sustain grid functionality. The effectiveness of the proposed architecture is validated through detailed MATLAB/Simulink simulations. Under regular conditions, the EMS achieves stable voltage regulation, balanced power sharing, and efficient energy curtailment. During fault conditions, the battery storage on both sides successfully supports the critical loads. The fuel cells are operated in power-controlled mode effectively up to their full rated 6kW capacity while the DC bus voltage stabilization is ensured by the battery energy storage systems. These results validate the proposed EMS as a robust and low-complexity solution for maritime DC microgrids, offering stable voltage regulation, effective load prioritization, and resilient operation of critical loads.
| elib-URL des Eintrags: | https://elib.dlr.de/224693/ | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dokumentart: | Zeitschriftenbeitrag | ||||||||||||||||||||||||
| Titel: | Modelling and Simulation of a Resilient and Straightforward Energy Management System for a DC Microgrid in a Cruise Ship Firezone | ||||||||||||||||||||||||
| Autoren: |
| ||||||||||||||||||||||||
| Datum: | 23 Mai 2026 | ||||||||||||||||||||||||
| Erschienen in: | Energies | ||||||||||||||||||||||||
| Referierte Publikation: | Ja | ||||||||||||||||||||||||
| Open Access: | Ja | ||||||||||||||||||||||||
| Gold Open Access: | Ja | ||||||||||||||||||||||||
| In SCOPUS: | Ja | ||||||||||||||||||||||||
| In ISI Web of Science: | Ja | ||||||||||||||||||||||||
| Band: | 19 | ||||||||||||||||||||||||
| DOI: | 10.3390/en19112512 | ||||||||||||||||||||||||
| Herausgeber: |
| ||||||||||||||||||||||||
| Verlag: | Multidisciplinary Digital Publishing Institute (MDPI) | ||||||||||||||||||||||||
| Name der Reihe: | Energies 2026 | ||||||||||||||||||||||||
| ISSN: | 1996-1073 | ||||||||||||||||||||||||
| Status: | veröffentlicht | ||||||||||||||||||||||||
| Stichwörter: | DC microgrid; cruise ship; energy management system; decentralized droop control; battery energy storage system; load shedding; PV curtailment; fuel cell; maritime power system; polluting emissions reduction | ||||||||||||||||||||||||
| HGF - Forschungsbereich: | Energie | ||||||||||||||||||||||||
| HGF - Programm: | Energiesystemdesign | ||||||||||||||||||||||||
| HGF - Programmthema: | Digitalisierung und Systemtechnologie | ||||||||||||||||||||||||
| DLR - Schwerpunkt: | Energie | ||||||||||||||||||||||||
| DLR - Forschungsgebiet: | E SY - Energiesystemtechnologie und -analyse | ||||||||||||||||||||||||
| DLR - Teilgebiet (Projekt, Vorhaben): | E - Energiesystemtechnologie | ||||||||||||||||||||||||
| Standort: | Oldenburg | ||||||||||||||||||||||||
| Institute & Einrichtungen: | Institut für Vernetzte Energiesysteme > Energiesystemtechnologie | ||||||||||||||||||||||||
| Hinterlegt von: | Vallabhaneni, Saikrishna | ||||||||||||||||||||||||
| Hinterlegt am: | 01 Jun 2026 10:04 | ||||||||||||||||||||||||
| Letzte Änderung: | 01 Jun 2026 10:04 |
Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags