elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Imprint | Privacy Policy | Accessibility | Contact | Deutsch
Fontsize: [-] Text [+]

Implementation and Results of Contractors' S-1C End-to-End System Calibration, Issue 1.0 (Report for IOCR)

Klenk, Patrick and Giez, Jakob and Schmidt, Kersten and Schwerdt, Marco and Pulella, Andrea and Nannini, Matteo and Prats, Pau (2025) Implementation and Results of Contractors' S-1C End-to-End System Calibration, Issue 1.0 (Report for IOCR). Project Report. S1-RP-DLR-0005.

Full text not available from this repository.

Abstract

As already done for S-1A in 2014 and S1-B in 2016, in addition to the commissioning of S-1C executed by ESA, an independent SAR system calibration has been performed by the Microwave and Radar Institute of the German Aerospace Center (DLR) in response to ESA's SoW as part of S-1C commissioning phase (CP) campaign. This independent calibration has once more been executed using both (i) the Institute's analysis and evaluation tools, already developed and applied successfully for calibrating Sentinel-1A/B in 2014 and 2016, and (ii) the same DLR reference targets (located west of Munich/Oberpfaffenhofen in South Germany) as for S-1A/B, as S-1C flies in the same orbit as its siblings. These DLR reference targets, a total of three transponders and three corner reflectors, were deployed related to the coverage of S-1A and have been maintained and successfully operated since launch of S-1A in April 2014.

The present calibration report summarizes all activities and results which are necessary in order to achieve an independent calibration of S-1C. These activities are based on the overall SAR system calibration and verification concept defined for S-1A and follows the strategy described by the in-orbit calibration plan.

This document reports the end-to-end S-1C calibration results achieved with the mission elements status as deployed at IOCR.

Item URL in elib:https://elib.dlr.de/222614/
Document Type:Monograph (Project Report)
Title:Implementation and Results of Contractors' S-1C End-to-End System Calibration, Issue 1.0 (Report for IOCR)
Authors:
AuthorsInstitution or Email of AuthorsAuthor's ORCID iDORCID Put Code
Klenk, PatrickPatrick.Klenk (at) dlr.dehttps://orcid.org/0000-0002-8284-2265UNSPECIFIED
Giez, JakobJakob.Giez (at) dlr.dehttps://orcid.org/0000-0002-2462-4550204801942
Schmidt, KerstenKersten.Schmidt (at) dlr.dehttps://orcid.org/0000-0001-7896-908XUNSPECIFIED
Schwerdt, MarcoMarco.Schwerdt (at) dlr.dehttps://orcid.org/0000-0002-0045-3726UNSPECIFIED
Pulella, AndreaAndrea.Pulella (at) dlr.dehttps://orcid.org/0000-0001-6295-617XUNSPECIFIED
Nannini, MatteoMatteo.Nannini (at) dlr.dehttps://orcid.org/0000-0003-3523-9639UNSPECIFIED
Prats, PauPau.Prats (at) dlr.dehttps://orcid.org/0000-0002-7583-2309UNSPECIFIED
Date:7 May 2025
Refereed publication:No
Open Access:No
Status:Published
Keywords:Sentinel-1, S1C, S1-C, Sentinel-1C, C-Band SAR, Calibration, Overall SAR System Calibration, DLR SAR Calibration Center
HGF - Research field:Aeronautics, Space and Transport
HGF - Program:Space
HGF - Program Themes:Earth Observation
DLR - Research area:Raumfahrt
DLR - Program:R EO - Earth Observation
DLR - Research theme (Project):R - SAR missions
Location: Oberpfaffenhofen
Institutes and Institutions:Microwaves and Radar Institute > Spaceborne SAR Systems
Deposited By: Klenk, Dr. Patrick
Deposited On:05 Feb 2026 14:22
Last Modified:05 Feb 2026 14:22

Repository Staff Only: item control page

Browse
Search
Help & Contact
Information
OpenAIRE Validator logo electronic library is running on EPrints
Website and database design: Copyright © German Aerospace Center (DLR). All rights reserved.