Effect of steam flow parameters on the partial load behaviour of a PCM storage

Dietz, Larissa and Bürger, Inga and Gutierrez Rojas, Andrea Lucia (2024) Effect of steam flow parameters on the partial load behaviour of a PCM storage. Journal of Energy Storage, 89, p. 111709. Elsevier. doi: 10.1016/j.est.2024.111709. ISSN 2352-152X.

[img] PDF - Published version
3MB

Official URL: https://www.sciencedirect.com/science/article/pii/S2352152X24012945?via%3Dihub

Abstract

To estimate the achievable thermal power in passive latent heat thermal energy storage (LH-TES) systems and the corresponding charging/discharging times for customised storage design and operation, relevant influencing parameters and their impact must be sufficiently known and understood. These parameters include not only the well-researched parameters on the phase change material (PCM) side, but also the parameters on the heat transfer fluid (HTF) side, such as the inlet temperature, the mass flow rate and the resulting heat transfer coefficient (HTC) between the HTF flow and the tube wall. For heat exchangers, these influences have been studied well, however for highly transient LH-TES studies are scarce. This article presents the influence of relevant parameters focusing on the ones related to the HTF side, using analytical and numerical parameter studies in Matlab®. The effect of different HTCs for varying flow conditions of the HTF in different zones of the tube is utilised to introduce the dominant heat transfer surface between the storage and the HTF (DHTS) as an indirect operating parameter. It corresponds to the area where the HTF phase change occurs and where most of the total energy is transferred. The numerical study indicates that the size of the dominant heat transfer area and thus the DHTS can be adapted by the HTF mass flow rate and the Temperature difference between the HTF inlet temperature and the PCM phase change temperature. Based on this knowledge, new conjugate design and operating strategies for a test rig with a nominal thermal power of 1 kW using the commercial PCM PLUSICE A133 as storage material are proposed. They lead to a peak shaving behaviour of the storage with defined charging and discharging times.

Item URL in elib:https://elib.dlr.de/203916/
Document Type:Article
Title:Effect of steam flow parameters on the partial load behaviour of a PCM storage
Authors:
AuthorsInstitution or Email of AuthorsAuthor's ORCID iDORCID Put Code
Dietz, LarissaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Bürger, IngaUNSPECIFIEDhttps://orcid.org/0000-0002-6091-0431160525398
Gutierrez Rojas, Andrea LuciaUNSPECIFIEDUNSPECIFIEDUNSPECIFIED
Date:22 April 2024
Journal or Publication Title:Journal of Energy Storage
Refereed publication:Yes
Open Access:Yes
Gold Open Access:No
In SCOPUS:Yes
In ISI Web of Science:Yes
Volume:89
DOI:10.1016/j.est.2024.111709
Page Range:p. 111709
Publisher:Elsevier
ISSN:2352-152X
Status:Published
Keywords:PCM , steam production, two-phase flow, latent heat storage
HGF - Research field:Energy
HGF - Program:Materials and Technologies for the Energy Transition
HGF - Program Themes:High-Temperature Thermal Technologies
DLR - Research area:Energy
DLR - Program:E SP - Energy Storage
DLR - Research theme (Project):E - Thermochemical Processes
Location: Stuttgart
Institutes and Institutions:Institute of Engineering Thermodynamics > Thermal Process Technology
Deposited By: Dietz, Larissa
Deposited On:29 May 2024 17:31
Last Modified:20 Jun 2024 08:14

Repository Staff Only: item control page