Dietz, Larissa und Bürger, Inga und Gutierrez Rojas, Andrea Lucia (2024) Effect of steam flow parameters on the partial load behaviour of a PCM storage. Journal of Energy Storage, 89, Seite 111709. Elsevier. doi: 10.1016/j.est.2024.111709. ISSN 2352-152X.
PDF
- Verlagsversion (veröffentlichte Fassung)
3MB |
Offizielle URL: https://www.sciencedirect.com/science/article/pii/S2352152X24012945?via%3Dihub
Kurzfassung
To estimate the achievable thermal power in passive latent heat thermal energy storage (LH-TES) systems and the corresponding charging/discharging times for customised storage design and operation, relevant influencing parameters and their impact must be sufficiently known and understood. These parameters include not only the well-researched parameters on the phase change material (PCM) side, but also the parameters on the heat transfer fluid (HTF) side, such as the inlet temperature, the mass flow rate and the resulting heat transfer coefficient (HTC) between the HTF flow and the tube wall. For heat exchangers, these influences have been studied well, however for highly transient LH-TES studies are scarce. This article presents the influence of relevant parameters focusing on the ones related to the HTF side, using analytical and numerical parameter studies in Matlab®. The effect of different HTCs for varying flow conditions of the HTF in different zones of the tube is utilised to introduce the dominant heat transfer surface between the storage and the HTF (DHTS) as an indirect operating parameter. It corresponds to the area where the HTF phase change occurs and where most of the total energy is transferred. The numerical study indicates that the size of the dominant heat transfer area and thus the DHTS can be adapted by the HTF mass flow rate and the Temperature difference between the HTF inlet temperature and the PCM phase change temperature. Based on this knowledge, new conjugate design and operating strategies for a test rig with a nominal thermal power of 1 kW using the commercial PCM PLUSICE A133 as storage material are proposed. They lead to a peak shaving behaviour of the storage with defined charging and discharging times.
elib-URL des Eintrags: | https://elib.dlr.de/203916/ | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dokumentart: | Zeitschriftenbeitrag | ||||||||||||||||
Titel: | Effect of steam flow parameters on the partial load behaviour of a PCM storage | ||||||||||||||||
Autoren: |
| ||||||||||||||||
Datum: | 22 April 2024 | ||||||||||||||||
Erschienen in: | Journal of Energy Storage | ||||||||||||||||
Referierte Publikation: | Ja | ||||||||||||||||
Open Access: | Ja | ||||||||||||||||
Gold Open Access: | Nein | ||||||||||||||||
In SCOPUS: | Ja | ||||||||||||||||
In ISI Web of Science: | Ja | ||||||||||||||||
Band: | 89 | ||||||||||||||||
DOI: | 10.1016/j.est.2024.111709 | ||||||||||||||||
Seitenbereich: | Seite 111709 | ||||||||||||||||
Verlag: | Elsevier | ||||||||||||||||
ISSN: | 2352-152X | ||||||||||||||||
Status: | veröffentlicht | ||||||||||||||||
Stichwörter: | PCM , steam production, two-phase flow, latent heat storage | ||||||||||||||||
HGF - Forschungsbereich: | Energie | ||||||||||||||||
HGF - Programm: | Materialien und Technologien für die Energiewende | ||||||||||||||||
HGF - Programmthema: | Thermische Hochtemperaturtechnologien | ||||||||||||||||
DLR - Schwerpunkt: | Energie | ||||||||||||||||
DLR - Forschungsgebiet: | E SP - Energiespeicher | ||||||||||||||||
DLR - Teilgebiet (Projekt, Vorhaben): | E - Thermochemische Prozesse | ||||||||||||||||
Standort: | Stuttgart | ||||||||||||||||
Institute & Einrichtungen: | Institut für Technische Thermodynamik > Thermische Prozesstechnik | ||||||||||||||||
Hinterlegt von: | Dietz, Larissa | ||||||||||||||||
Hinterlegt am: | 29 Mai 2024 17:31 | ||||||||||||||||
Letzte Änderung: | 20 Jun 2024 08:14 |
Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags