Sofi, Tasdeeq und Gude, Maria R. und Wierach, Peter und Martin, Isabel und Lorenzo, Martin (2023) An Efficient Procedure for Bonding Piezoelectric Transducers to Thermoplastic Composite Structures for SHM Application andIts Durability in Aeronautical Environmental Conditions. Sensors, 23 (10), Seite 4784. Multidisciplinary Digital Publishing Institute (MDPI). doi: 10.3390/s23104784. ISSN 1424-8220.
PDF
- Verlagsversion (veröffentlichte Fassung)
41MB |
Offizielle URL: https://www.mdpi.com/1424-8220/23/10/4784
Kurzfassung
Piezoceramic transducers (PCTs) bonded to carbon fiber-reinforced plastic (CFRP) composite structures must be durable as well as remain properly bonded to the structure in order to provide reliable data for accurate guided-wave-based structural health monitoring (SHM) of aeronautical components. The current method of bonding transducers to composite structures through epoxy adhesives faces some shortcomings, such as difficult reparability, lack of weldability, longer curing cycles, and shorter shelf life. To overcome these shortcomings, a new efficient procedure for bonding the transducers to thermoplastic (TP) composite structures was developed by utilizing TP adhesive films. Application-suitable TP films (TPFs) were identified and characterized through standard differential scanning calorimetry (DSC) and single lap shear (SLS) tests to study their melting behavior and bonding strength, respectively. Special PCTs called acousto-ultrasonic composite transducers (AUCTs) were bonded to high-performance TP composites (carbon fiber Poly-Ether-Ether-Ketone) coupons with a reference adhesive (Loctite EA 9695) and the selected TPFs. The integrity and durability of the bonded AUCTs in aeronautical operational environmental conditions (AOEC) were assessed in accordance to the standard Radio Technical Commission for Aeronautics DO-160. The AOEC tests performed were operating low and high temperatures, thermal cycling, hot-wet, and fluid susceptibility tests. The health and bonding quality of the AUCTs were evaluated by the electro-mechanical impedance (EMI) spectroscopy method and ultrasonic inspections. The AUCT defects were created artificially and their influence on the susceptance spectra (SS) was measured to compare them with the AOEC-tested AUCTs. The results show that a small change occurred in the SS characteristics of the bonded AUCTs in all of the adhesive cases after the AOEC tests. After comparing the changes in SS characteristics of simulated defects with that of the AOEC-tested AUCTs, the change is relatively smaller and therefore it can be concluded that no serious degradation of the AUCT or the adhesive layer has occurred. It was observed that the most critical tests among the AOEC tests are the fluid susceptibility tests, which can cause the biggest change in the SS characteristics. Comparing the performance of the AUCTs bonded with the reference adhesive and the selected TPFs in the AOEC tests, it was seen that some of the TPFs, e.g., Pontacol 22.100 outperforms the reference adhesive, while the other TPFs have similar performance to that of the reference adhesive. Therefore, in conclusion, the AUCTs bonded with the selected TPFs can withstand the operational and environmental conditions of an aircraft structure, and hence, the proposed procedure is easily installed, reparable, and a more reliable method of bonding sensors to aircraft structures.
elib-URL des Eintrags: | https://elib.dlr.de/201885/ | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dokumentart: | Zeitschriftenbeitrag | ||||||||||||||||||||||||
Titel: | An Efficient Procedure for Bonding Piezoelectric Transducers to Thermoplastic Composite Structures for SHM Application andIts Durability in Aeronautical Environmental Conditions | ||||||||||||||||||||||||
Autoren: |
| ||||||||||||||||||||||||
Datum: | 16 Mai 2023 | ||||||||||||||||||||||||
Erschienen in: | Sensors | ||||||||||||||||||||||||
Referierte Publikation: | Ja | ||||||||||||||||||||||||
Open Access: | Ja | ||||||||||||||||||||||||
Gold Open Access: | Ja | ||||||||||||||||||||||||
In SCOPUS: | Ja | ||||||||||||||||||||||||
In ISI Web of Science: | Ja | ||||||||||||||||||||||||
Band: | 23 | ||||||||||||||||||||||||
DOI: | 10.3390/s23104784 | ||||||||||||||||||||||||
Seitenbereich: | Seite 4784 | ||||||||||||||||||||||||
Verlag: | Multidisciplinary Digital Publishing Institute (MDPI) | ||||||||||||||||||||||||
ISSN: | 1424-8220 | ||||||||||||||||||||||||
Status: | veröffentlicht | ||||||||||||||||||||||||
Stichwörter: | composite materials; acousto-ultrasonic transducers; thermoplastic adhesive films; sensor bonding; electro-mechanical susceptance; durability and integrity; structural health monitoring (SHM) | ||||||||||||||||||||||||
HGF - Forschungsbereich: | Luftfahrt, Raumfahrt und Verkehr | ||||||||||||||||||||||||
HGF - Programm: | Luftfahrt | ||||||||||||||||||||||||
HGF - Programmthema: | Komponenten und Systeme | ||||||||||||||||||||||||
DLR - Schwerpunkt: | Luftfahrt | ||||||||||||||||||||||||
DLR - Forschungsgebiet: | L CS - Komponenten und Systeme | ||||||||||||||||||||||||
DLR - Teilgebiet (Projekt, Vorhaben): | L - Strukturwerkstoffe und Bauweisen | ||||||||||||||||||||||||
Standort: | Braunschweig | ||||||||||||||||||||||||
Institute & Einrichtungen: | Institut für Systemleichtbau > Multifunktionswerkstoffe | ||||||||||||||||||||||||
Hinterlegt von: | Wierach, Prof. Dr. Peter | ||||||||||||||||||||||||
Hinterlegt am: | 22 Jan 2024 09:37 | ||||||||||||||||||||||||
Letzte Änderung: | 26 Jan 2024 12:47 |
Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags