Klenk, Patrick and Schmidt, Kersten and Kraus, Thomas and Steinbrecher, Ulrich and Schwerdt, Marco (2021) TandDEM-X Calibration Assessment after Redundancy Switch. In: Proceedings of the European Conference on Synthetic Aperture Radar, EUSAR. European Conference on Synthetic Aperture Radar (EUSAR), 2021-03-29 - 2021-04-01, Leipzig, Germany. ISSN 2197-4403.
Full text not available from this repository.
Abstract
After more than nine years of successful radar operations in space, a first major contingency passivated the TanDEM-X satellite's SAR instrument in July 2019. Subsequent investigations led to the decision to switch to the redundant instrument chain, i.e. using the redundant radio-frequency electronics for future radar operations. Here, we report results of the necessary re-assessment of the calibration of the instrument. The redundancy switch did not have a significant impact on the performance of the radar instrument. In particular, the radiometric accuracy remains excellent. The calibration factor differs by -0.9 dB in comparison to the previously operated nominal instrument chain
Item URL in elib: | https://elib.dlr.de/130055/ | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Document Type: | Conference or Workshop Item (Speech) | ||||||||||||||||||
Title: | TandDEM-X Calibration Assessment after Redundancy Switch | ||||||||||||||||||
Authors: |
| ||||||||||||||||||
Date: | April 2021 | ||||||||||||||||||
Journal or Publication Title: | Proceedings of the European Conference on Synthetic Aperture Radar, EUSAR | ||||||||||||||||||
Refereed publication: | Yes | ||||||||||||||||||
Open Access: | No | ||||||||||||||||||
Gold Open Access: | No | ||||||||||||||||||
In SCOPUS: | Yes | ||||||||||||||||||
In ISI Web of Science: | No | ||||||||||||||||||
ISSN: | 2197-4403 | ||||||||||||||||||
Status: | Published | ||||||||||||||||||
Keywords: | SAR, synthetic-aperture radar, TerraSAR-X, TanDEM-X, contingency mitigation, calibration, absolute radiometric calibration, absolute calibration factor, redundancy, redundancy switch, antenna pattern, RCS, absolute RCS, Terra-SAR-X mission, internal calibration, external calibration, LTSM | ||||||||||||||||||
Event Title: | European Conference on Synthetic Aperture Radar (EUSAR) | ||||||||||||||||||
Event Location: | Leipzig, Germany | ||||||||||||||||||
Event Type: | international Conference | ||||||||||||||||||
Event Dates: | 2021-03-29 - 2021-04-01 | ||||||||||||||||||
Organizer: | VDE | ||||||||||||||||||
HGF - Research field: | Aeronautics, Space and Transport | ||||||||||||||||||
HGF - Program: | Space | ||||||||||||||||||
HGF - Program Themes: | Earth Observation | ||||||||||||||||||
DLR - Research area: | Raumfahrt | ||||||||||||||||||
DLR - Program: | R EO - Earth Observation | ||||||||||||||||||
DLR - Research theme (Project): | R - TSD/TDX Calibration and projekt support (old) | ||||||||||||||||||
Location: | Oberpfaffenhofen | ||||||||||||||||||
Institutes and Institutions: | Microwaves and Radar Institute > Spaceborne SAR Systems | ||||||||||||||||||
Deposited By: | Klenk, Dr. Patrick | ||||||||||||||||||
Deposited On: | 06 Nov 2019 16:39 | ||||||||||||||||||
Last Modified: | 30 Nov 2021 14:05 |
Repository Staff Only: item control page