Assessment of Quality of MIPAS ESA V8 Products Before Full Mission Reprocessing

Raspollini, Piera and Barbara, F. and Bianchini, M. and Birk, Manfred and Castelli, Elisa and Ceccherini, Simone and Dehn, Angelika and Gai, Marco and Dinelli, Bianca Maria and Dudhia, Anu and Flaud, Jean-Marie and Höpfner, M. and Hubert, Daan and Keppens, Arno and Kiefer, Michael and Kleinert, Anne and Moore, David and Papandrea, E. and Perron, Gaetan and Piro, Alessandro and López-Puertas, M. and Oelhaf, H. and Pettinari, Paolo and Remedios, J. and Ridolfi, Marco and Sgheri, L. and Wagner, Georg and Wetzel, Gerald and Zoppetti, Nicole (2018) Assessment of Quality of MIPAS ESA V8 Products Before Full Mission Reprocessing. ATMOS-2018, 26.-29. Nov. 2018, Salzburg, Österreich.

Full text not available from this repository.

Abstract

The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) is a limb-viewing infrared Fourier transform spectrometer that operated from 2002 to 2012 onboard the ENVISAT satellite. The maintenance and the upgrade of both L1 and L2 ESA processors are accomplished in the frame of the Quality Working Group, where a fruitful collaboration among Level 1, Level 2 and validation teams can be exploited. Recently both ESA L1 and L2 processors have been updated, as well as spectroscopic database and some Absorption cross-sections. In addition to the products already present in V7 dataset (temperature and the VMR of H2O, O3, HNO3, CH4, N2O, NO2, CFC-11, CFC-12, N2O5, ClONO2, HCFC-22, COF2, CF4, HCN and CCl4), the VMR of six additional species (OCS, CH3Cl, HDO, C2H2, C2H6, COCl2) will be provided in V8 dataset. In preparation of V8 full mission reprocessing, three Diagnostic Datasets have been generated to check the performances of all L1, L2 processors and the new auxiliary data. The analysis of these Diagnostic Datasets and the comparison with previous full mission dataset V7 will be used to perform a first assessment of the quality of the new V8 products. In the paper special focus will be given to the new species.

Item URL in elib:https://elib.dlr.de/124858/
Document Type:Conference or Workshop Item (Speech)
Title:Assessment of Quality of MIPAS ESA V8 Products Before Full Mission Reprocessing
Authors:
AuthorsInstitution or Email of AuthorsAuthors ORCID iD
Raspollini, PieraIstituto di Fisica Applicata 'Nello Carrara' (IFAC) del Consiglio Nazionale delleRicerche (CNR), Firenze (Italy)UNSPECIFIED
Barbara, F.IFAC-CNR, Florence, ItalyUNSPECIFIED
Bianchini, M.ISC-CNR, Florence, ItalyUNSPECIFIED
Birk, Manfredmanfred.birk (at) dlr.deUNSPECIFIED
Castelli, ElisaISAC-CNRUNSPECIFIED
Ceccherini, SimoneIFAC-CNRUNSPECIFIED
Dehn, AngelikaESA-ESRIN, Via Galileo Galilei, 00044 Frascati, ItalyUNSPECIFIED
Gai, MarcoIstituto di Fisica Applicata 'Nello Carrara' (IFAC) del Consiglio Nazionale delleRicerche (CNR), Firenze (Italy)UNSPECIFIED
Dinelli, Bianca MariaIstituto di Scienza dell’Atmosfera e del Clima (ISAC) del Consiglio Nazionale delle Ricerche (CNR), Bologna, ItalyUNSPECIFIED
Dudhia, AnuAtmospheric, Oceanic and Planetary Physics – Clarendon Laboratory – Oxford University, UKUNSPECIFIED
Flaud, Jean-MarieLISA, CNRS/Universites ParisUNSPECIFIED
Höpfner, M.Institut für Meteorologie und Klimaforschung, FZ KarlsruheUNSPECIFIED
Hubert, DaanBelgian institute fpr Space Aeronomy, BelgieUNSPECIFIED
Keppens, ArnoBIRA-IASBUNSPECIFIED
Kiefer, MichaelKIT-IMK, H.-v.-Helmholtz-Platz 1, 76344 Leopoldshafen, GermanyUNSPECIFIED
Kleinert, AnneKarlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK), 76021 Karlsruhe, GermanyUNSPECIFIED
Moore, DavidUNSPECIFIEDUNSPECIFIED
Papandrea, E.Istituto di Scienza dell’Atmosfera e del Clima (ISAC) del Consiglio Nazionale delle Ricerche (CNR), Bologna, ItalyUNSPECIFIED
Perron, GaetanABB BOMEM Inc., 585 Blvd. Charest East, Quebéc, CanadaUNSPECIFIED
Piro, AlessandroUNSPECIFIEDUNSPECIFIED
López-Puertas, M.Instituto de Astrofísica de Andalucía (IAA), Granada, SpainUNSPECIFIED
Oelhaf, H.Karlsruhe Institute of Technology, Institute for Meteorology and Climate Research, Karlsruhe, GermanyUNSPECIFIED
Pettinari, PaoloISAC-CNRUNSPECIFIED
Remedios, J.Department of Physics & Astronomy, University of LeicesterUNSPECIFIED
Ridolfi, MarcoDipartimento di Fisica Chimica ed Inorganica, University of Bologna, ItalyUNSPECIFIED
Sgheri, L.Istituto di Scienza dell’Atmosfera e del Clima (ISAC) del Consiglio Nazionale delle Ricerche (CNR), Bologna, ItalyUNSPECIFIED
Wagner, GeorgGeorg.Wagner (at) dlr.deUNSPECIFIED
Wetzel, GeraldKarlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK), 76021 Karlsruhe, GermanyUNSPECIFIED
Zoppetti, NicoleIstituto di Fisica Applicata 'Nello Carrara' (IFAC) del Consiglio Nazionale delleRicerche (CNR), Firenze (Italy)UNSPECIFIED
Date:November 2018
Refereed publication:No
Open Access:No
Gold Open Access:No
In SCOPUS:No
In ISI Web of Science:No
Status:Published
Keywords:MIPAS/ENVISAT, atmospheric trace gases, L1 and L2 processor, data quality, Fourier transform spectrometer, satellite remote sensing
Event Title:ATMOS-2018
Event Location:Salzburg, Österreich
Event Type:international Conference
Event Dates:26.-29. Nov. 2018
HGF - Research field:Aeronautics, Space and Transport
HGF - Program:Space
HGF - Program Themes:Earth Observation
DLR - Research area:Raumfahrt
DLR - Program:R EO - Erdbeobachtung
DLR - Research theme (Project):Vorhaben Spectroscopic Methods in Remote Sensing
Location: Oberpfaffenhofen
Institutes and Institutions:Remote Sensing Technology Institute > Experimental Methods
Deposited By: Birk, Manfred
Deposited On:14 Dec 2018 17:40
Last Modified:14 Dec 2018 17:40

Repository Staff Only: item control page

Browse
Search
Help & Contact
Information
electronic library is running on EPrints 3.3.12
Copyright © 2008-2017 German Aerospace Center (DLR). All rights reserved.