elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Impressum | Datenschutz | Kontakt | English
Schriftgröße: [-] Text [+]

A filter calibration method for laser-scanned weld toe geometries

Renken, Finn und Jung, Matthias und Ehlers, Sören und Braun, Moritz (2024) A filter calibration method for laser-scanned weld toe geometries. Applications in Engineering Science, 20. Elsevier. doi: 10.1016/j.apples.2024.100200. ISSN 2666-4968.

[img] PDF - Verlagsversion (veröffentlichte Fassung)
37MB

Kurzfassung

The scanning of weld seams can be used to evaluate the local weld toe geometry for fatigue assessments. Laser scanned weld seam profiles often contain noise which complicates the accurate measurement of the weld toe geometry. For that reason, filtering of the scanned data is necessary. The issue at hand is that a filtering method can significantly affect the measurement results. Therefore, a calibration of the filter input parameters is needed. In this study, a calibration method for filtered laser-scanned weld profiles is presented by using artificial weld toe geometries. The adjustment of different filter functions is achieved by using an optimization method on predefined weld toes with an artificial noise. The resulting input data for the filter functions is tested on a real specimen to verify the method. Through the calibration method it is possible to achieve satisfactory measurement results with precisely set input parameters for the filter functions. The most suitable filter functions for the measurement of the weld toe are the Gaussian and the Lowpass filter. Both functions are adequate as a universally applicable filter. For the evaluation of the measurement results of the radii and angles, a tolerance range is introduced, which is defined by the theoretically minimum measurable radii and angles. Using an adjusted Lowpass filter and a point distance of 0.07 mm set by the laser scanner, a measurement within the tolerance range of 0.2 mm is achievable for the weld toe radius. For the weld toe angle, the tolerance range of 1.5° is achieved for the majority of measurements.

elib-URL des Eintrags:https://elib.dlr.de/211592/
Dokumentart:Zeitschriftenbeitrag
Titel:A filter calibration method for laser-scanned weld toe geometries
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Renken, FinnInstitute for Ship Structural Design and Analysis, Hamburg University of Technology, 21073 Hamburg, Germany; finn.renken (at) tuhh.de (F.R.)NICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Jung, MatthiasFraunhofer Institute for Mechanics of Materials IWMNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Ehlers, Sörensoeren.ehlers (at) dlr.dehttps://orcid.org/0000-0001-5698-9354NICHT SPEZIFIZIERT
Braun, Moritzmoritz.braun (at) dlr.dehttps://orcid.org/0000-0001-9266-1698NICHT SPEZIFIZIERT
Datum:Dezember 2024
Erschienen in:Applications in Engineering Science
Referierte Publikation:Ja
Open Access:Ja
Gold Open Access:Ja
In SCOPUS:Ja
In ISI Web of Science:Ja
Band:20
DOI:10.1016/j.apples.2024.100200
Verlag:Elsevier
ISSN:2666-4968
Status:veröffentlicht
Stichwörter:Weld toe measurement, Laser scanning, Filter calibration, Data smoothing, Universal filter
HGF - Forschungsbereich:Luftfahrt, Raumfahrt und Verkehr
HGF - Programm:Verkehr
HGF - Programmthema:keine Zuordnung
DLR - Schwerpunkt:Verkehr
DLR - Forschungsgebiet:V - keine Zuordnung
DLR - Teilgebiet (Projekt, Vorhaben):V - keine Zuordnung
Standort: Geesthacht
Institute & Einrichtungen:Institut für Maritime Energiesysteme
Hinterlegt von: Tanvir, Mahamudul Hasan
Hinterlegt am:10 Jan 2025 08:36
Letzte Änderung:15 Jan 2025 13:55

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.