elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Impressum | Datenschutz | Kontakt | English
Schriftgröße: [-] Text [+]

Thermal performance response and heat load redistribution mechanism of a deep U-type borehole heat exchanger in heating systems

Chen, Chaofan und Witte, Francesco und Taherdangkoo, Reza und Cai, Wanlong und Chen, Shuang und Kong, Yanlong und Shao, Haibing und Hofmann, Mathias und Nagel, Thomas (2025) Thermal performance response and heat load redistribution mechanism of a deep U-type borehole heat exchanger in heating systems. Applied Energy (382). Elsevier. doi: 10.1016/j.apenergy.2024.125216. ISSN 0306-2619.

[img] PDF - Verlagsversion (veröffentlichte Fassung)
1MB

Kurzfassung

Deep closed-loop borehole heat exchanger systems have gained significant attention in recent years for extracting geothermal energy to effectively heat buildings, e.g. by integrating them into district heating systems. In this work, a 3D numerical model of the pilot Deep U-type Borehole Heat Exchanger (DUBHE) system that was recently implemented in Xi’an, China, is established based on the OpenGeoSys software. The model is fully validated by 2-months of monitoring data from the pilot project. Then, a thermodynamic heat pump model is further coupled to investigate the transient thermal response of the DUBHE to the heat pump’s off-design performance. Subsequently, dynamic operations in a district heating system are simulated to evaluate the flexibility of the DUBHE-couple heat pump system. For the first time, the mechanism of heat load distribution by the heat pump and the behavior of heat load redistribution during operation are clarified between the subsurface DUBHE and the heat pump. The maximum sustainable heating power of the whole system is found to be around 780 kW in 120-day operation with the working fluid R410A and the required feed flow temperature of 65°C in the heat pump. With increasing operation time, the heat load distributed to the DUBHE decreases by more than 21% in 120 days due to the decrease in the heat pump performance. The R600 heat pump has the best performance and efficiency among four different working fluids, but leads to a 3.4°C reduction in the outflow temperature of the DUBHE compared to the R410A heat pump. This over-extracted performance of the DUBHE poses a challenge to its sustainable operation in terms of the circulation fluid temperature of the DUBHE. In the two operation patterns of integrating into the district heating system, the subsurface DUBHE can provide both around 70% of the total heat power to the district heating system. The average annual COP is 0.2 higher with low feed flow temperature to the district heating system and more frequent shutdown operation, showing significant flexibility in integrating the DUBHE-coupled heat pump system into the district heating system.

elib-URL des Eintrags:https://elib.dlr.de/211365/
Dokumentart:Zeitschriftenbeitrag
Titel:Thermal performance response and heat load redistribution mechanism of a deep U-type borehole heat exchanger in heating systems
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Chen, ChaofanNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Witte, Francescofrancesco.witte (at) dlr.dehttps://orcid.org/0000-0003-4019-0390NICHT SPEZIFIZIERT
Taherdangkoo, RezaNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Cai, WanlongNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Chen, ShuangBGRNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Kong, YanlongInstitute of Geology and Geophysics, CASNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Shao, HaibingufzNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Hofmann, Mathiashofmann (at) iet.tu-berlin.dehttps://orcid.org/0000-0002-1541-3874NICHT SPEZIFIZIERT
Nagel, ThomasUFZNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Datum:1 Januar 2025
Erschienen in:Applied Energy
Referierte Publikation:Ja
Open Access:Ja
Gold Open Access:Nein
In SCOPUS:Ja
In ISI Web of Science:Ja
DOI:10.1016/j.apenergy.2024.125216
Verlag:Elsevier
ISSN:0306-2619
Status:veröffentlicht
Stichwörter:Deep U-type Borehole Heat Exchanger (DUBHE), Ground source heat pump, Building heating, Heat load redistribution, District heating system
HGF - Forschungsbereich:Energie
HGF - Programm:Energiesystemdesign
HGF - Programmthema:Digitalisierung und Systemtechnologie
DLR - Schwerpunkt:Energie
DLR - Forschungsgebiet:E SY - Energiesystemtechnologie und -analyse
DLR - Teilgebiet (Projekt, Vorhaben):E - Energiesystemtechnologie
Standort: Oldenburg
Institute & Einrichtungen:Institut für Vernetzte Energiesysteme > Energiesystemanalyse, OL
Hinterlegt von: Witte, Francesco
Hinterlegt am:06 Jan 2025 12:17
Letzte Änderung:06 Jan 2025 12:17

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.