Radiometric Accuracy and Stability of Sentinel-1A Determined using Point Targets

Schmidt, Kersten und Tous Ramon, Núria und Schwerdt, Marco (2018) Radiometric Accuracy and Stability of Sentinel-1A Determined using Point Targets. International Journal of Microwave and Wireless Technologies. Cambridge University Press. doi: 10.1017/S1759078718000016. ISSN 1759-0787.

[img] PDF
642kB

Offizielle URL: https://www.cambridge.org/core/journals/international-journal-of-microwave-and-wireless-technologies/article/radiometric-accuracy-and-stability-of-sentinel1a-determined-using-point-targets/3E32B48BC0FD1B43B280DF9405DA4387

Kurzfassung

Sentinel-1A is a space-borne SAR system developed in the frame of the Copernicus Program. The German Aerospace Center supported the radiometric and polarimetric calibration of Sentinel-1A by the analysis of point target responses of several acquisitions considering different modes, beams and polarization channels. An elevation dependent bias, which had not been properly predicted by the used antenna model, was found for all investigated modes. Offsets of up to 2 dB were determined during the SAR instrument calibration phase, in particular for low and high elevation angles. Therefore, in order to correct these elevation biases, a radiometric refinement was carried out by ESA in November 2015. After that, Sentinel-1A radiometric accuracy and long-term stability were analysed over a period of 1.5 years. For this period, the absolute calibration factor and the channel imbalance were determined for the main imaging mode. Moreover, a slight drift of the derived calibration factor was observed starting from July 2016. At the same time an anomaly was detected in the front-end affecting several transmit and receive modules in one tile. The radiometric behaviour of Sentinel-1A should therefore be monitored for a longer period of time, especially to detect potential degradation effects of the SAR instrument.

elib-URL des Eintrags:https://elib.dlr.de/115839/
Dokumentart:Zeitschriftenbeitrag
Titel:Radiometric Accuracy and Stability of Sentinel-1A Determined using Point Targets
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Schmidt, KerstenKersten.Schmidt (at) dlr.dehttps://orcid.org/0000-0001-7896-908XNICHT SPEZIFIZIERT
Tous Ramon, NúriaNuria.TousRamon (at) dlr.dehttps://orcid.org/0000-0002-0450-0438NICHT SPEZIFIZIERT
Schwerdt, MarcoMarco.Schwerdt (at) dlr.dehttps://orcid.org/0000-0002-0045-3726NICHT SPEZIFIZIERT
Datum:9 März 2018
Erschienen in:International Journal of Microwave and Wireless Technologies
Referierte Publikation:Ja
Open Access:Ja
Gold Open Access:Nein
In SCOPUS:Ja
In ISI Web of Science:Ja
DOI:10.1017/S1759078718000016
Verlag:Cambridge University Press
ISSN:1759-0787
Status:veröffentlicht
Stichwörter:SAR System calibration. Sentinel-1, radiometric accuracy and stability, radiometric calibration, channel imbalance, Long term System monitoring
HGF - Forschungsbereich:Luftfahrt, Raumfahrt und Verkehr
HGF - Programm:Raumfahrt
HGF - Programmthema:Erdbeobachtung
DLR - Schwerpunkt:Raumfahrt
DLR - Forschungsgebiet:R EO - Erdbeobachtung
DLR - Teilgebiet (Projekt, Vorhaben):R - SAR-Missionen
Standort: Oberpfaffenhofen
Institute & Einrichtungen:Institut für Hochfrequenztechnik und Radarsysteme > Satelliten-SAR-Systeme
Hinterlegt von: Schmidt, Dr. Kersten
Hinterlegt am:22 Nov 2017 11:13
Letzte Änderung:02 Nov 2023 11:56

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.