Schwerdt, Marco und Schmidt, Kersten und Tous Ramon, Núria und Klenk, Patrick und Yague-Martinez, Nestor und Prats, Pau und Zink, Manfred und Geudtner, Dirk (2017) Independent System Calibration of Sentinel-1B. Remote Sensing, 9 (6). Multidisciplinary Digital Publishing Institute (MDPI). doi: 10.3390/rs9060511. ISSN 2072-4292.
Dieses Archiv kann nicht den Volltext zur Verfügung stellen.
Offizielle URL: http://www.mdpi.com/2072-4292/9/6/511
Kurzfassung
Sentinel-1B is the second of two C-Band Synthetic Aperture Radar (SAR) satellites of the Sentinel-1 mission, launched in April 2016 - two years after the launch of the first satellite, Sentinel-1A. In addition to the commissioning of Sentinel-1B executed by the European Space Agency (ESA), an independent system calibration was performed by the German Aerospace Center (DLR) on behalf of ESA. Based on an efficient calibration strategy and the different calibration procedures already developed and applied for Sentinel-1A, extensive measurement campaigns were executed by initializing and aligning DLR's reference targets deployed on the ground. This paper describes the different activities performed by DLR during the Sentinel-1B commissioning phase and presents the results derived from the analysis and the evaluation of a multitude of data takes and measurements.
elib-URL des Eintrags: | https://elib.dlr.de/113939/ | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dokumentart: | Zeitschriftenbeitrag | ||||||||||||||||||||||||||||||||||||
Titel: | Independent System Calibration of Sentinel-1B | ||||||||||||||||||||||||||||||||||||
Autoren: |
| ||||||||||||||||||||||||||||||||||||
Datum: | Mai 2017 | ||||||||||||||||||||||||||||||||||||
Erschienen in: | Remote Sensing | ||||||||||||||||||||||||||||||||||||
Referierte Publikation: | Ja | ||||||||||||||||||||||||||||||||||||
Open Access: | Ja | ||||||||||||||||||||||||||||||||||||
Gold Open Access: | Ja | ||||||||||||||||||||||||||||||||||||
In SCOPUS: | Ja | ||||||||||||||||||||||||||||||||||||
In ISI Web of Science: | Ja | ||||||||||||||||||||||||||||||||||||
Band: | 9 | ||||||||||||||||||||||||||||||||||||
DOI: | 10.3390/rs9060511 | ||||||||||||||||||||||||||||||||||||
Verlag: | Multidisciplinary Digital Publishing Institute (MDPI) | ||||||||||||||||||||||||||||||||||||
ISSN: | 2072-4292 | ||||||||||||||||||||||||||||||||||||
Status: | veröffentlicht | ||||||||||||||||||||||||||||||||||||
Stichwörter: | internal calibration; geometric and radiometric calibration; polarimetric calibration; antenna model verification; antenna pointing determination; Sentinel-1; radiometric accuracy; calibration targets | ||||||||||||||||||||||||||||||||||||
HGF - Forschungsbereich: | Luftfahrt, Raumfahrt und Verkehr | ||||||||||||||||||||||||||||||||||||
HGF - Programm: | Raumfahrt | ||||||||||||||||||||||||||||||||||||
HGF - Programmthema: | Erdbeobachtung | ||||||||||||||||||||||||||||||||||||
DLR - Schwerpunkt: | Raumfahrt | ||||||||||||||||||||||||||||||||||||
DLR - Forschungsgebiet: | R EO - Erdbeobachtung | ||||||||||||||||||||||||||||||||||||
DLR - Teilgebiet (Projekt, Vorhaben): | R - SAR-Missionen | ||||||||||||||||||||||||||||||||||||
Standort: | Oberpfaffenhofen | ||||||||||||||||||||||||||||||||||||
Institute & Einrichtungen: | Institut für Hochfrequenztechnik und Radarsysteme > Satelliten-SAR-Systeme | ||||||||||||||||||||||||||||||||||||
Hinterlegt von: | Schwerdt, Dr.-Ing. Marco | ||||||||||||||||||||||||||||||||||||
Hinterlegt am: | 06 Sep 2017 17:11 | ||||||||||||||||||||||||||||||||||||
Letzte Änderung: | 02 Nov 2023 14:40 |
Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags