elib
DLR-Header
DLR-Logo -> http://www.dlr.de
DLR Portal Home | Impressum | Datenschutz | Kontakt | English
Schriftgröße: [-] Text [+]

A fast double shutter for CCD-based metrology

Geisler, Reinhard (2017) A fast double shutter for CCD-based metrology. In: Proceedings of SPIE - The International Society for Optical Engineering. 31st International Congresson High-Speed lmaging and Photonics, 07.-10. Nov. 2016, Osaka, Japan. doi: 10.1117/12.2269099. ISBN 9781510611009. ISSN 0277-786X.

Dieses Archiv kann nicht den Volltext zur Verfügung stellen.

Offizielle URL: http://ilasseurope.org/events/the-31st-international-congress-on-high-speed-imaging-and-photonics-ichsip-osaka-japan-7-10-nov-2016/

Kurzfassung

Image based metrology such as Particle Image Velocimetry (PIV) depends on the comparison of two images of an object taken in fast succession. Cameras for these applications provide the so-called 'double shutter' mode: One frame is captured with a short exposure time and in direct succession a second frame with a long exposure time can be recorded. The difference in the exposure times is typically no problem since illumination is provided by a pulsed light source such as a laser and the measurements are performed in a darkened environment to prevent ambient light from accumulating in the long second exposure time. However, measurements of self-luminous processes (e.g. plasma, combustion ... ) as weil as experiments in ambient light are difficult to perform and require special equipment (external shutters, highspeed image sensors, multi-sensor systems ... ). Unfortunately, all these methods incorporate different drawbacks such as reduced resolution, degraded image quality, decreased light sensitivity or increased susceptibility to decalibration. In the solution presented here, off-the-shelf CCD sensors are used with a special timing to combine neighbouring pixels in a binning-like way. As a result, two frames of short exposure time can be captured in fast succession. They are stored in the on-chip vertical register in a line-interleaved pattern, read out in the common way and separated again by software. The two resultant frames are completely congruent; they expose no insensitive lines or line shifts and thus enable sub-pixel accurate measurements. A third frame can be captured at the full resolution analogue to the double shutter technique. Image based measurement techniques such as PIV can benefit from this mode when applied in bright environments. The third frame is useful e.g. for acceleration measurements or for particle tracking applications. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

elib-URL des Eintrags:https://elib.dlr.de/118544/
Dokumentart:Konferenzbeitrag (Vortrag)
Zusätzliche Informationen:Proceedings of SPIE 0277-786X; Vol. 10328; Paper DOI: 10.1117/12.2269099; Published by SPIE; Proc. of SPIE Val. 10328 1032801-1
Titel:A fast double shutter for CCD-based metrology
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Geisler, ReinhardReinhard.Geisler (at) dlr.dehttps://orcid.org/0009-0006-8838-3713NICHT SPEZIFIZIERT
Datum:2017
Erschienen in:Proceedings of SPIE - The International Society for Optical Engineering
Referierte Publikation:Ja
Open Access:Nein
Gold Open Access:Nein
In SCOPUS:Ja
In ISI Web of Science:Ja
DOI:10.1117/12.2269099
ISSN:0277-786X
ISBN:9781510611009
Status:veröffentlicht
Stichwörter:CCD, double shutter, Particle Image Velocimetry (PIV), Particle Tracking Velocimetry (PTV)
Veranstaltungstitel:31st International Congresson High-Speed lmaging and Photonics
Veranstaltungsort:Osaka, Japan
Veranstaltungsart:internationale Konferenz
Veranstaltungsdatum:07.-10. Nov. 2016
HGF - Forschungsbereich:Luftfahrt, Raumfahrt und Verkehr
HGF - Programm:Luftfahrt
HGF - Programmthema:Flugzeuge
DLR - Schwerpunkt:Luftfahrt
DLR - Forschungsgebiet:L AR - Aircraft Research
DLR - Teilgebiet (Projekt, Vorhaben):L - Simulation und Validierung (alt)
Standort: Göttingen
Institute & Einrichtungen:Institut für Aerodynamik und Strömungstechnik > Experimentelle Verfahren, GO
Hinterlegt von: Bachmann, Barbara
Hinterlegt am:26 Jan 2018 14:42
Letzte Änderung:11 Aug 2023 09:53

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.