Benchmark Testing of ONERA and DLR Pressure Sensitive Paints for Unsteady/Instationary Flows

Merienne, Marie-Claire und Le Sant, Yves und Molton, Pascal und Carpels, Yves und Beck, Walter und Klein, Christian und Henne, Ulrich und Sachs, Werner (2016) Benchmark Testing of ONERA and DLR Pressure Sensitive Paints for Unsteady/Instationary Flows. MOTAR DLR/ONERA Cooperation, 24. - 25. May 2016, Lille, France.

Dieses Archiv kann nicht den Volltext zur Verfügung stellen.

Kurzfassung

Aim: Some years ago, in the framework of the Motar Cooperation Agreement between ONERA and DLR, it had been agreed to carry out comparison testing of the two instationary PSP methods on a common test configuration with an unsteady flow produced in a suitable wind tunnel. The results from this comparison would form the basis for a benchmarking of the two different approaches, leading to an aid in decision-making as to which method is better suited for a particular application. / Test configuration: For many years there has been interest at ONERA on the (quasi) two-dimensional unsteady transonic flow in a channel with strong interactions between an oscillating shock and a separated boundary layer: various diagnostic methods were used in measurements on their S8Ch transonic wind tunnel at ONERA Meudon (Schlieren, pressure sensors, PIV, LDV), including also PSP with Ru/AA paint (uPSP). Flow separation of the boundary layer is produced over a convex contour profile (a bump) on the floor of the tunnel, with the subsequent flow acceleration leading to formation of a downstream shock wave. The sectional area of a second throat, situated downstream of the bump, is varied periodically (ca. 15 Hz or higher) by rotation of an elliptical rod (cam) placed downstream of the throat position, leading to forced upstream pressure fluctuations and hence an oscillation (movement in flow direction) in the shock position. The resulting pressure fluctuations on the bump can then be measured with the help of pressure sensors (Kulite) fixed in the floor, and also with PSP coated on the floor. / Procedure/Approach: The floor can also be coated with the DLR iPSP paint. As with ONERA, there exists sufficient optical access for placement of the DLR excitation LEDs and cameras adjacent to or above the test section. PSP measurements were then be carried out with a new set of measurements using both ONERA and DLR paints, consecutively. / Results: Pressure measurements with Kulite and iPSP/uPSP are compared. Phase correlation is good, but there remain some differences in amplitude for both paints. Static and instationary calibration were carried out on samples of both paints; the latter showed no phase loss up to 120 Hz, although the amplitude with iPSP dropped due to surface heating by the LED over time. Fourier analyses of Kulite and PSP showed good agreement. A table was compiled with a summary of characteristics for both paints: there is no “better” paint, since the choice is governed mainly by desired application.

elib-URL des Eintrags:https://elib.dlr.de/104500/
Dokumentart:Konferenzbeitrag (Vortrag)
Titel:Benchmark Testing of ONERA and DLR Pressure Sensitive Paints for Unsteady/Instationary Flows
Autoren:
AutorenInstitution oder E-Mail-AdresseAutoren-ORCID-iDORCID Put Code
Merienne, Marie-ClaireONERA, Fundamental and Experimental Aerodynamics Department, Meudon, FranceNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Le Sant, YvesONERA, FranceNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Molton, PascalONERA, Fundamental and Experimental Aerodynamics Department, Meudon, FranceNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Carpels, YvesNICHT SPEZIFIZIERTNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Beck, Walterwalter.beck (at) dlr.deNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Klein, Christianchristian.klein (at) dlr.deNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Henne, Ulrichulrich.henne (at) dlr.deNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Sachs, Wernerwerner.sachs (at) dlr.deNICHT SPEZIFIZIERTNICHT SPEZIFIZIERT
Datum:2016
Referierte Publikation:Nein
Open Access:Nein
Gold Open Access:Nein
In SCOPUS:Nein
In ISI Web of Science:Nein
Status:veröffentlicht
Stichwörter:fast PSP, bench mark testing, S8 wind tunnel, buffeting
Veranstaltungstitel:MOTAR DLR/ONERA Cooperation
Veranstaltungsort:Lille, France
Veranstaltungsart:Andere
Veranstaltungsdatum:24. - 25. May 2016
HGF - Forschungsbereich:Luftfahrt, Raumfahrt und Verkehr
HGF - Programm:Luftfahrt
HGF - Programmthema:Flugzeuge
DLR - Schwerpunkt:Luftfahrt
DLR - Forschungsgebiet:L AR - Aircraft Research
DLR - Teilgebiet (Projekt, Vorhaben):L - Simulation und Validierung (alt)
Standort: Göttingen
Institute & Einrichtungen:Institut für Aerodynamik und Strömungstechnik > Experimentelle Verfahren
Hinterlegt von: Bachmann, Barbara
Hinterlegt am:11 Jul 2016 09:24
Letzte Änderung:22 Dez 2016 11:29

Nur für Mitarbeiter des Archivs: Kontrollseite des Eintrags

Blättern
Suchen
Hilfe & Kontakt
Informationen
electronic library verwendet EPrints 3.3.12
Gestaltung Webseite und Datenbank: Copyright © Deutsches Zentrum für Luft- und Raumfahrt (DLR). Alle Rechte vorbehalten.